Garland Commercial Ranges Ltd.
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
General Inquiries 1-905-624-0260
USA Sales, Parts and Service 1-800-424-2411
Canadian Sales 1-888-442-7526
Canada or USA Parts/Service 1-800-427-6668
“D”
TOP VIEW
38"
[965mm]
25-3/8"
[645mm]
54-9/16"
[1386mm]
3/4" N.P.T.
GAS INLET
3/4" REAR
GAS INLET
1" REAR
GAS INLET
7-3/4"
[197mm]
2"
[51mm]
3/4"
[19mm]
(includes
motor)
FLUE: 2-3/8" x 5"
[60mm x 127mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
34"
[864mm]
SINGLE DECK
FRONT VIEW
6-1/4"
[159mm]
DOUBLE DECK
FRONT VIEW
32-1/8"
[816mm]
32-1/8"
[816mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
32-1/8"
[816mm]
14-3/4"
[375mm]
35-7/16"
[900mm]
Form# SCOGS (07/02/14)
Sunre Series Gas Convection Oven
Gas Input Ratings shown here are for installations up to
3,000 ft. (915m) above sea level. Specify altitudes over
3,000 ft.
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V, 3/4 HP, 1725 rpm; 2-speed motor option, 1140
and 1725 rpm, 60Hz.
3. A 6 ft. line cord is provided for each 120V deck with a (NEMA
#5-15P) plug.
4. It is recommended a separate 15 AMP circuit for each 120V unit.
Model
Int. Dimensions : In (mm) Ext. Dimensions: In (mm) Ship Wt Ship Dim.
W H D W H ** D (w/motor) Lbs/kg Cubic Ft.
SCO-GS-10S 29 (736) 24 (610) 24 (610) 38 (965) 57-1/2 (1461) 41-1/4 (1048) 750/341 80
SCO-GS-20S 29(736) 24(610) 24(610) 38(965) 70 -1/2 (1791) 41-1/4 (1048) 1500/682 160
** Height with or without standard casters. Height with low prole casters (double deck) is 68-1/2" (1740mm).
Models
Input Ratings, Natural & Propane Operating Pressure *
Electrical
Specications
BTU/hr kW Equiv. Gas Inlet Natural Propane 120V/1Ph.
Single Deck 53,000 15.53 (1) @ 3/4" NPT
4" WC
(10 mbar)
10" WC
(25 mbar)
(1)@9.8A
Double Deck 106,000 31.06 (1) @1" NPT
(2)@9.8A
*Maximum Pressure 13.8" WC @ 7F (21°C)
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.
These appliances are intended for commercial use by professionally trained personnel.
Installation Notes:
Combustible & Non-Combustible
Wall Clearances:
Sides 1" (25mm) Back 3" (76mm)
Entry Clearances: In (mm)
Crated 4 4 -1/ 2 (113 0) Uncrated 32-1/2 (826)